A first-timer's guide

Reading in Sectra

Setup, workflow, image tools, every keyboard shortcut and a map of the menus, in one searchable place.

Answers come only from this guide and can be wrong; keys can differ at your site.

1
The short version

Start here

If you only read one section, read this one. These are the features and habits that make the biggest difference.

The five features to learn first

KeyFeatureWhy it matters
XCrosshair (anatomic linking)Links equivalent planes across current and prior studies so you scroll matched anatomy. Often not on by default.
NumPad +Sync groupsManually links stacks so scroll, zoom, pan and window/level move together. Your fallback when X misses a prior. NumPad − removes a stack.
;Send comparisonsSends the priors on screen to the comparison field of the report. Sectra does not do this automatically; the key is ;.
Mouse wheelSpine labelingLabels start at C2. Scroll to drop to lumbar levels, start at L5/S1, double-click the last level to finish.
Shift+M / EscFast view switchingShift+M opens MPR; Esc leaves 3D/MPR back to 2D.

The recommended reading workflow

  1. 1Open the current study and give relevant priors a few seconds to load (they start loading as soon as you open the exam).
  2. 2Press X to turn on anatomic linking.
  3. 3If a prior is not linked, rehang (switch back to the first display protocol) or link it manually with NumPad +.
  4. 4Review priors deliberately rather than opening everything; only the ones on screen are cited.
  5. 5Before signing, with the report open and the priors displayed, send the comparisons with ;.
  6. 6Sign in the dictation system. Need to fix something? Reopen the exam from your history within a few minutes and it reopens for editing.
Takeaways
  • • Learn crosshair linking, sync groups and sending comparisons before anything else.
  • • Much of the useful functionality is not on the toolbars; a lot of the speed comes from keyboard shortcuts.
  • • Manual synchronization is an essential fallback skill, not a rare workaround.
  • • Stay close to your organization's defaults at first (see Customization).
  • • Expect a learning curve, then real gains once these become routine.
Switching from another PACS?

During a PACS transition, don't run Sectra and the old PACS worklist side by side for clinical work unless your site says that combination is supported; it can behave unpredictably.

Day-one checklist

0 of 7 done
2
Orientation

How the pieces fit together

Sectra replaces the image viewer and worklist. You still dictate in your reporting system and see the chart in the EHR. Knowing which piece does what makes most early problems easy to diagnose.

ComponentWhat it is / does
IDS7The Sectra diagnostic workstation: image windows, display (hanging) protocols, measurement and navigation tools.
Information windowSectra's main window for worklists, patient and exam information, history, and the Auto / Dictate sync buttons. Sometimes called the ROP.
Matrix windowThumbnail overview. Press F3 while dictating to see this patient's priors and prior reports without other patients from the list.
Quick windowA quick image view, mainly for technologist quality checks or as a companion display on a non-diagnostic monitor.
Dictation (e.g. PowerScribe 360)Where you dictate and sign. Sectra sends exam context to it and to the EHR.
Reporting integration layerSoftware that links Sectra and the dictation system. Listens passively, validates the report at signing, and passes comparisons across when you send them.
EHRReceives context from Sectra. The final report goes to the EHR, which then sets the Sectra status to Final.
UniViewSectra's web viewer. Shows all images, radiology and non-radiology.
Display protocols (DPs)Sectra's hanging protocols, built by your organization. You can switch between DPs for an exam.
Context flow in one line

Sectra → dictation and EHR (context). The integration layer listens and validates at sign-off. Sign → final report sent (immediately with Send Now, or after a short delay) → EHR → Sectra shows Final.

3
Orientation

Icons, toolbars and menus

Sectra's own icons, what each does and where it lives. Many buttons have a small arrow beside them that opens related tools. Hover any button in Sectra to see its name and key.

Kinds of menu

  • Menu barThe menus along the top of a window (File, View, Tools…).
  • ToolbarThe row of buttons under the menu bar.
  • Pop-up menuA right-click menu: on an image (Image pop-up), on a stack (Stack pop-up), on an exam in the patient history list (Patient History pop-up) or on a thumbnail (Thumbnail pop-up).
  • ToolboxThe grid of tool icons at the top of the right-click menu; it changes with the modality.
  • SubmenuIn Menus & Toolbars, an entry with this icon holds more tools; click into it.

Information window toolbar

  • Log OffLog out of Sectra.
  • MatrixOpen the Matrix window: the patient's exams with a thumbnail of every series.
  • ImagesBring up the image window.
  • ChatOpen Sectra chat to share a case with a colleague.
  • PatientsPatient-level tools; hover it in Sectra to see the exact action at your site.
  • RefreshF5Refresh the worklist.
  • Search (panel)Ctrl+FOpen the search panel to pick the fields you search by.
  • SearchCtrl+GRun a search; the small arrow beside it offers more search options.
  • TeachingTTeaching files: tag the exam with a keyword or add it to a list.
  • < CaseCtrl+NumPad .Previous case.
  • Case >Ctrl+NumPad 0Next case.
  • DictateF12Open the report for this exam in your dictation system. The arrow beside it holds the Auto options.
  • ParkSet the exam aside to come back to; it's listed under the Parked Examinations menu.
  • Assign ToAssign the selected exam to a radiologist, yourself included (there's no Mark Read).
  • BackAlt+LeftStep back to what you were viewing, like a browser.
  • ForwardAlt+RightStep forward again.
  • ExamOpen the Examination window for the selected exam.

Image window toolbar

  • CloseClose the images.
  • ChatSectra chat.
  • Case >Ctrl+NumPad 0Next case.
  • < LayoutNumPad .Previous layout (greyed out on the first one).
  • Layout >NumPad 0Next layout.
  • ThumbnailsShow or hide the series thumbnails along the bottom (highlighted when on).
  • ArrowAArrow annotation; the arrow beside it holds the other annotations.
  • DistanceDDistance measurement; the arrow beside it holds the other measurements.
  • 2 x 2Ctrl+2Tile the stack; the arrow beside it picks other tilings.
  • CrosshairXShow Crosshair: anatomic linking across views and priors.
  • GraphicsShow or hide measurements and annotations (highlighted when shown).
  • MultipleMultiple Graphics Creation: keep the tool active to draw several in a row.
  • DictateF12Dictate the report.
  • ParkSet the exam aside to come back to.
  • Options…Ctrl+Shift+OOpen Options (all personal settings).
  • Go to Display ProtocolOpen the Display Protocol Editor for this hanging.

Report toolbar (Information window)

  • New blank reportStart a new, empty report for the exam. The first step of a preliminary report (see Dictation and exam status).
  • Feather (preliminary report)After New blank report, click it to make the report preliminary.

Measure menu (right-click an image › Measure)

  • DistanceDStraight-line measurement.
  • Orthogonal DistanceShift+DTwo perpendicular diameters.
  • AngleNMeasure an angle.
  • AreaOutline a region to get its area.
  • ROI CircleCircular region of interest with its values.
  • ROI AreaFreehand region of interest.
  • Histogram CircleHCircular ROI with a histogram of pixel values.
  • RatioRatio of two lengths.
  • Cardiothoracic RatioAlt+DHeart and chest widths, and their ratio.
  • Show Ortho GraphicsShow orthopedic template graphics.
  • Distance to NippleMammography: distance from a finding to the nipple.
  • Photodynamic Therapy (PDT)PDT measurement (ophthalmology).
  • ETDRS GridRetinal grid overlay (ophthalmology).
  • NM ROI AreaNuclear medicine region of interest, freehand.
  • NM ROI CircleNuclear medicine region of interest, circular.
  • CalibrateSet the scale from a feature of known size, so measurements are true.
  • Reset CalibrationGo back to the image's own scale.

More commands you can add to menus (Options › Menus & Toolbars)

  • About…Sectra version and system details.
  • Add Examination Info to ReportPut the exam's details into the report.
  • Add LayoutCtrl+JAdd a layout to the hanging.
  • Add to Report PresentationCtrl+Shift+NSave the image to the presentation linked to the report.
  • Align Image LeftLine the image up against the left edge.
  • Align Image RightLine the image up against the right edge.
  • Align Linked MPR ViewsAlt+QLine up linked MPR views.
  • ArrowAArrow annotation.
  • Auto-Download Current CaseDownload the current case's images automatically.
  • Change Reason…Reject analysis: change why an image was rejected.
  • Confirm RejectionReject analysis: confirm a rejected image.
  • Chat WindowOpen Sectra chat.
  • CircleOCircle annotation.
  • Clear PaletteCtrl+Alt+WRemove a color palette and go back to grayscale.
  • Clinical ApplicationsOpen the clinical applications for this image.
  • Copy to ClipboardCopy the image.
  • Copy IDS7 URL to ClipboardA link that opens this exam in IDS7.
  • Copy UniView URL to ClipboardA link that opens this exam in UniView, the web viewer.
  • Create Breast Implant MaskMammography: mask an implant.
  • Crop AutomaticallyCtrl+Shift+ACrop the image to its content.
  • Crop ImageCrop by hand.

The Matrix window at a glance

Do you need the Matrix window? No, it's optional. Most readers find the priors in the Information window and on the diagnostic monitors enough; some like the Matrix on a separate screen to see the patient's whole exam history at once.

AreaWhat it's for
Patient history (left)Every exam for the patient, by date.
Series rows (right)One row of series thumbnails per exam; the current exam's row is highlighted.
Layouts (top left)The layouts in the current hanging; click one to work on it.
Partitions (top middle)The panes of the selected layout. Drag a series thumbnail into a pane to hang it there.
Display protocol box (toolbar)Shows and switches the hanging protocol in use.
Thumbnail size (bottom right)A slider to make thumbnails bigger or smaller.

Its toolbar has Information (back to the Information window), Images, Refresh, < Case / Case >, < Layout / Layout >, and + / − Layout to add or remove layouts.

4
Setup

Getting in: install, login and desktop sync

The desktop icon

  • The Sectra icon is usually pushed automatically to workstations on the network (including VPN). Keep the PC on and connected; installs can take a while to arrive.
  • Some workstations will be offline or fail to install during a mass push. Your PACS team can push the install on demand.
Never hand-install Sectra

Manual installs break third-party integrations and desktop sync. Always go through your PACS team.

Logging in

  1. 1Launch Sectra from the integrated desktop icon (the integrated version is what enables sync).
  2. 2Choose the radiologist role your PACS team designates. Use it regardless of subspecialty, even if its name suggests otherwise. Another role can leave you without hanging protocols, the right menus or your site's hotkeys.
  3. 3Click More options under the login box and check the box to log on to external desktop sync applications. This links the dictation system and the EHR. Without it, the Auto / Dictate and auto-next buttons don't appear.
  4. 4Log in. Your role shows next to your name in the upper left of the Information window; check it.
Picked the wrong role?

There is a checkbox to automatically choose your last enrollment type. If you logged in with the wrong role, uncheck it so you can pick the right role next time. No hanging protocols at all is the giveaway.

No desktop-sync option even after expanding More options?

Contact your PACS team. One known cause is a duplicate account where only one copy is in the correct group.

Access and permissions

  • Before go-live you may only be able to log in, without worklists or images, so you can't test monitor placement yet. Just confirm the icon is there and you can log in with the right role.
  • A “no permission to view patient data” error on a worklist after you've been given access means your account isn't fully provisioned. Report it to your PACS team.
  • A warning that the reporting integration is out of sync with IDS7 is common early on, even when nothing else is running. Because the integration only listens passively, Sectra can't confirm sync and warns. Report it if it persists.
5
Setup

Monitor layout

Getting the diagnostic images onto the diagnostic monitors is the most common early problem. Sort it out before your first clinical day.

  • Monitor layout is workstation-specific (by hostname), not user-specific. Every workstation you read from (office, home, other sites) needs to be right.
  • There is usually one standard layout. If your setup matches it, it should just work. Non-standard setups (a different monitor count, three diagnostic monitors, monitors on the opposite sides) typically need a PACS admin; users can't reassign image-window monitors themselves.
  • Typical symptom: images open on the side (non-diagnostic) monitors.
  • Fixing it takes a few minutes of PACS time per workstation, so ask early rather than on your first clinical morning.
  • Office and home stations can behave differently; one may work while the other doesn't.
Never trust a monitor number

Windows, the graphics driver and Sectra each count monitors their own way, and the numbers can change after a cable, dock, KVM switch or reboot. Sectra can also split one wide screen into two virtual monitors, so its count may not match the screens on the desk. Identify each screen by its position, resolution and orientation instead.

Diagnostic vs other screens

Diagnostic (image) displaysOther displays
JobReading imagesInformation window, EHR, dictation, email, chat
HardwareMedical-grade, high resolution, usually a matched portrait pair with a built-in light sensorOrdinary monitors, usually landscape
CalibrationDICOM grayscale curve, checked by the QA programNot calibrated for reading
How to spot themHighest resolution, often a medical brand badge and QA software in the system trayThe screen with the taskbar, where the mouse lands at login
  • Never read images on a non-diagnostic screen. If a hanging puts images on the Information window screen, fix the setup before reading.
  • The diagnostic displays should be a matched set: same model, resolution, orientation and calibration. Mixing in an ordinary monitor gives side-by-side images different brightness.
  • Your medical physicist sets the calibration targets. Common guidance is a maximum brightness of about 350 cd/m² for radiography and 420 for mammography, with displays in one station within about 10% of each other.
  • Keep the reading room dim (about 20 lux of diffuse light), with no lamp or window reflecting in the diagnostic screens.

Get Windows right first

Sectra builds its layout from what Windows reports, so check Settings › System › Display (right-click the desktop › Display settings) on each workstation. If IT has locked these settings, report what you see rather than working around it.

  • Multiple displays: Extend these displays (not duplicate).
  • Click Identify, then drag the screen tiles into the same left-to-right order as the desk, top edges aligned and portrait screens drawn tall. Otherwise the mouse jumps to the wrong screen.
  • Every screen at its native resolution (marked Recommended), and scaling at 100% on the diagnostic displays; anything else blurs images and can throw off measurements.
  • Portrait panels set to Portrait in Windows, not rotated in the monitor's own menu.
  • Make the Information window/EHR screen the main display, so the taskbar, login boxes and pop-ups land there instead of on images.
  • Diagnostic displays plugged into the dedicated graphics card, not the motherboard ports.
  • Turn off power saving that dims or sleeps screens mid-read, and night-light or color filters on diagnostic screens.
  • Leave the display QA (calibration) software running, and don't change brightness with the monitor's buttons.

Check with a real study

  1. 1Open a multi-series study with a prior (a CT with a comparison works well).
  2. 2Images fill the diagnostic displays only; nothing hangs on the Information window screen.
  3. 3Current and prior are on the sides you expect.
  4. 4No “not all images shown” warning icon on the toolbar; it usually means the hanging expects more monitors than the station has.
  5. 5The mouse crosses between screens where they physically touch.
  6. 6Log out and back in: the layout comes back the same.
  • If Sectra asks for the physical monitor size, enter it: true size and same-size comparisons depend on it.
  • More than two image monitors can need an extra license, so a station without it can behave differently.
  • A small label on each screen's bezel (“Image L”, “Image R”, “Worklist”) makes phone support much faster.

The Information window

  • Opens by default on the rightmost non-diagnostic monitor (often a portrait monitor). You can drag it elsewhere for the session.
  • Changing its default position usually needs PACS admin access.
  • Some display preferences, such as font size, follow your account rather than the workstation. A size chosen for a portrait monitor at home can look far too big on a landscape monitor at work. Change it in Advanced Configuration (search “font”); keep diagnostic displays at their native resolution.
6
Daily workflow

Worklists and the Information window

  • Worklists are built by your organization. If one includes the wrong sites or modalities, report it with what it should contain.
  • When you open an exam it usually drops off the worklist. That's expected: its status changes and most worklists don't include that status. Find it again in your history.
  • There is no “Mark Read.” To claim an exam, assign it to yourself. The right-click menus (worklist results and patient history) also offer Reading Physician › Set Me as Reading Physician.
  • You can add columns such as Station name, which can tell scanners apart better than Referring unit, or Exam Description in your History list, where it isn't shown by default. Changing columns detaches you from the shared column configuration (see Customization).
  • Handy keys: F5 refresh worklist, Ctrl+F search panel, Ctrl+Shift+F advanced search, Ctrl+E extended patient search, Ctrl+Y current RIS window.

Finding your worklist

  • In the Information window, open All Worklists, then Role Worklists for the lists for your rotation or role.
  • Drag the worklists you use into Favorites at the top left of the Information window for quick access.
  • Buttons under the worklist title (for example 3 STAT, 1 ASAP, 2 To Read) show counts and filter the list by priority or status. A blue bar then says how many exams are hidden; click it to remove the filter. The counts also help you decide when to switch lists.
  • Worklist groups collect the lists you use most at the top of the worklist tree; you can set one up per rotation. A list can be in several groups; drag and drop to add lists or reorder them.
  • Quick filters limit a list to the exams that match. Pick several and you see exams matching any of them.
  • The filter boxes under the column headings aren't case-sensitive. * matches any characters, unverified matches one character, and | means “or” (for example CT|MR). They work in the patient history list too, for example to show only one modality or similar body parts.
  • The History list holds your last 100 opened exams, newest first. It can't be cleared or renamed.
StatusTypically means
Exam BegunThe technologist has started; images may be incomplete.
Exam EndedAcquisition finished; ready to read.
LockedAnother radiologist has the exam open.
DraftA trainee has drafted a report that isn't signed yet (not visible in the EHR).
PreliminaryA preliminary report has been released to the EHR.

Status names and which ones your worklists show are set up by your organization, so yours may differ.

Searching for studies

  • Type an MRN, patient name, date of birth or accession number in the search bar.
  • Or press Ctrl+F (the Search button) and pick the fields to search by.
  • Change the two default search fields in Options › Search Panel. Setting the MRN match to “contains” instead of “is” means you can skip leading zeros.

The parts of the Information window

PartWhat it shows
Worklist resultsEvery matching exam in the selected worklist.
Patient history listAll studies for the selected patient. A green arrow marks the current (base) exam, the one the image window is built around. Click an exam once to show its report on the right; double-click it, or click Images, to open it.
Thumbnail listA thumbnail for each series in the study.
Worklist treeAll worklists at System, Role and User level. Role lists hold what needs reading; User lists are yours (handy for saving interesting cases).
FavoritesWorklists and studies you dragged there for quick access.
Seeing an exam's report
  • • In the Information window, click the exam once in the patient history list: its report shows on the right.
  • • While reading, press F3 (Matrix) to see the patient's priors and their reports without other patients from the list.
  • • In the image window, Show Documents (Alt+D) shows the exam's reports and documents.
  • • On a prior's image, right-click › Show Documents opens that prior's report right there, without looking over at the Information window.
Seeing one row per patient?

With Show one row per patient on, several exams for one patient collapse into one row. Turn it off (Information window menu bar › View › Show one row per patient) so every exam gets its own row.

  • Click a column header to sort, and sort back afterwards (worklists usually sort by priority, then by when the technologist finished). Type in the row under the headers to filter.
  • In many versions: bold exams match the worklist, gray ones no longer match, italics are in the archive, a red dot marks STAT, and a clock marks an exam scheduled for later. Ctrl-click selects several exams.
  • A worklist can be given a template that sets its columns and default sort order (for example class, then priority, then date/time). Ask your PACS administrator rather than re-sorting by hand each day.
  • Don't rely on the STAT dot alone: emergency and inpatient exams aren't always ordered STAT, so a list or filter showing only STAT exams can miss some of them.
  • A reading mark on an exam means someone else already has it, or its report, open.

More worklist tools

ToolWhereWhat it's for
Hold / Clear HoldInformation window toolbar › HoldPut an exam on hold with a reason (e.g. priors ordered, addendum, PACS review). Ask how your group uses it.
Seat AssignmentsRight-click an exam › Seat AssignmentsAssign an exam to a reading seat, or clear it; for groups that share work by seat.
Pending ListRight-click an exam › Pending ListA personal holding list, separate from Park.
Clear Parked Examinations ListTools menuEmpty your parked list.
Priority / Clear PriorityTools › PrioritySet or clear an exam's priority.
BounceInformation window toolbarMove an exam between two worklists that have been paired (e.g. spines between MSK and Neuro). Where no pair is set up, it does nothing.
Turnaround indicatorsWorklist columnsSome worklists show turnaround (SLA) timers; check whether yours do.

The Matrix button, next to Log off in the Information window, opens the Matrix window: a list of the patient's prior studies with thumbnails for each series, which you can drag into specific panes of your display.

Where the Auto and Dictate buttons are

On the Information window ribbon, roughly in the middle of the top section, not on the toolbar above the images. If the Information window is in landscape and very wide, the small down-arrow that reveals them disappears; narrow the window to get it back. From the keyboard, Dictate is F11.

Batch reading: assigning several exams to yourself

Turn Auto-dictate off before assigning multiple exams

With automatic dictation on, right-clicking to assign an exam immediately opens a report each time. It gets glitchy and the assignment may not hold.

  1. 1Turn off the Auto (lightning bolt) / auto-dictate button.
  2. 2Right-click and assign the batch of exams to yourself.
  3. 3Go to your unread-exams worklist and turn both Auto buttons on.
  4. 4Read through the batch; the next exam and its report open automatically.
  5. 5Interrupted (a STAT, a call)? Toggle Auto off before going to another worklist, then back on when you return.
7
Daily workflow

Dictation and exam status

Opening and closing reports

  • Reports sync to the right exam when you click Dictate (F11 in Sectra), or automatically when Auto is on.
  • Auto-next buttons appear only once desktop sync is on and the dictation system has opened with Sectra.
  • Discarding a report in the dictation system does not close the exam in Sectra, and closing the images does not discard the report. Close each side yourself.
  • There's no standard setting to close an exam when you sign it. With both Auto buttons on and reading from a list, signing moves to the next exam, which closes the current one. Whether more is possible depends on how desktop sync is set up; ask PACS.
  • Next Status and Case (Status menu) sets the exam's status and opens the next case in one step.
  • If you're warned that several studies share one accession number, check which study is open before you dictate.

The status lifecycle

You do thisSectra status becomes
Open the reportReport Open
Save a draftDraft
Discard the reportBack to Completed
SignReport Pending
Click Send Now, or wait a few minutesFinal report goes to the EHR, which updates Sectra to Final
  • You can't set Report Pending by hand; only signing through desktop sync sets it.
  • Editing after signing: within the send delay, open the exam from your history; it reopens for editing (status back to Report Open).
  • Addendum stuck in Draft? If you open an addendum and delete it but the status stays Draft, open it again and delete it a second time; it returns to Final.

Making a preliminary report

  1. 1With the exam open, go to the report toolbar in the Information window.
  2. 2Click New blank report (the page with a star).
  3. 3Click the feather icon to make it a preliminary report (status Preliminary).
Watch for hotkey clashes with your dictation system

PowerScribe 360 hardcodes F7 (spelling) and F12 (sign). In Sectra F7 is previous series set and Dictate is F11, so only F7 clashes; you can disable PowerScribe's F7 with its Custom Keys application.

8
Daily workflow

Comparisons in the report

The biggest workflow change for many readers: some viewers send prior-exam information to the report every time you change priors. Sectra does not.

  1. 1Have the report open.
  2. 2Display the prior(s) you want to cite in the image windows.
  3. 3Run Insert All Visible Comparison Examinations into Report (;). It's a Sectra command, so the comparison field doesn't need to be selected.
  4. 4The integration layer receives it and fills in the comparison field.

Good to know

  • If no prior is displayed, or no report is open, the key does nothing (the command is disabled).
  • Only priors actually on screen are sent. Many readers like this: open lots of priors, then cite only the ones you really compared.
  • Insert Examination into Report (one exam) is Ctrl+Shift+Alt+K.
  • Comparisons are not sent automatically at sign-off, so build the habit before signing.
  • When no prior is shown, ' (apostrophe) inserts “None available” into the report.
  • Taking priors off screen doesn't update the field to “no priors”; change it by hand. Updates can take a few seconds to arrive.
  • Some readers use a mouse or keyboard macro that sends comparisons and then signs. Test the timing between keystrokes carefully.
9
Daily workflow

Priors and prefetch

  • When you open an exam, relevant priors (as defined by the display protocol) start loading immediately; older ones usually arrive within seconds.
  • Sectra can know an older exam exists (its metadata) before its images are on hand. Those may need to be retrieved, which takes a moment.
  • Prefetch usually runs when an exam is scheduled or arrives, pulling likely-relevant priors ahead of time. It only applies to exams scheduled after it was switched on, so recent ED cases are the best place to see it working.
  • If a prior arrives after you open the exam, it may not be linked automatically; rehang or link it manually (see Image tools).
  • Priors are colour-coded by how recent they are: mustard for the newest comparison, then persimmon, raspberry and grape. An optional green border marks the current exam's images.
  • On a series thumbnail, a blue dot means it hasn't been opened in an image window yet (not the same as unreviewed); a green outline means it's on screen in a partition.
  • Older exams on the long-term archive are marked with an archive icon in the patient history list. Right-click one › Retrieve from Archive, or double-click it. Progress shows beside the exam and the icon goes once every image is back; press F5 if the images don't open. Exams marked offline need importing instead.
10
Reading images

Image tools: linking, sync, spine, views

Crosshair linking (X)

  • Labelled Show Crosshair; it automatically links equivalent planes in the current and prior exams. A button at the top of the image window shows whether it's on.
  • Best for CT, MR, neuro, spine and MSK comparisons; many readers call it the most valuable hidden feature.
  • It is often not on by default in hanging protocols.
  • Ctrl+X shows the linked crosshair; L shows the localizer (a line marking the current plane on the other views).
  • Shift+Q (Navigate to Cursor) triangulates: it jumps every view to the point under the pointer. Shift + double-click can set the crosshair too.
Prior not linking?
  • • Make sure both Show Crosshair and Show Linked Crosshair are active.
  • • If the prior was still loading when you opened the exam, rehang: switch back to the first display protocol in the list. Sectra remembers everything you did to an exam, so just reopening isn't enough.
  • • Still not linked? Link it manually with NumPad +.

Sync groups (NumPad +)

  • Press NumPad + on a stack to add it to a sync group, then on every other stack you want linked. NumPad − removes a stack (“No Sync Group”).
  • Linked stacks share scrolling, zoom, pan and window/level.
  • Use it whenever automatic linking misbehaves; especially useful for longitudinal oncology, PET/CT and follow-ups.
  • More groups: Ctrl+NumPad 1–4 assign Sync Group 1–4. Ctrl+NumPad + turns synchronization on. Alt+Q aligns linked MPR views.

Spine labeling

  1. 1Start the spine labeling tool (Y). Labels start at C2 by default.
  2. 2With the tool active, scroll the mouse wheel to drop to lower levels.
  3. 3For a lumbar spine, start at L5/S1.
  4. 4Double-click the final level to finish (if double-clicking doesn't end it, press Enter). Labels then propagate across the examination.

To remove the labels, go back to the series where you placed them.

Switching views

KeyAction
Shift+MMPR
Shift+A / C / SAxial / coronal / sagittal MPR
Shift+33D
EscExit 3D/MPR, back to 2D
VQuick volume
FToggle fusion (in 3D: feet view; P posterior view)
- / Shift+-Slab / slab properties
MPR, 3D and slab keys

MPR is Shift+M and 3D is Shift+3; Ctrl+M is Sharpen edges. Ctrl+1–3 pick slab presets (CT AVG 3 / MIP 5 / MIP 10; MR AVG 3 / MIP 5; mammography MIP on Ctrl+1).

More viewing tips

  • Reformats on the fly: multiplanar reformats are easy, which helps when a CT was acquired in an awkward plane.
  • Plain films: you can open a stack of CR images.
  • Matrix mode: press F3 while dictating to see the patient's priors and prior reports.

More image tools

ToolWhat it's for
Current vs comparison markingNewer versions mark the current exam and comparisons with different colors or borders. Learn yours, so a prior is never read as the current study.
Substack Filter (Ctrl+Q)Splits a combined stack into substacks, e.g. by phase, echo or b-value, and steps between them.
Toggle Data (MPR / fusion)Switch which dataset is shown.
Remove Couch (Ctrl+Alt+C)Removes the CT table from 3D and MPR views.
Automatic MPR alignmentNewer versions align MPR views automatically; Alt+Q aligns linked views by hand.
Reset Manual Crosshair Link CorrectionMPR Synchronization menu: undo a manual crosshair correction when linked positions drift.
Reset Manual Series OrderRight-click an exam: put series back in their original order.
Force Examination TypeRight-click an exam: tell Sectra what the exam is so the right display protocol applies. It changes how the exam hangs; ask before using.
Show DICOM Elements (Ctrl+Shift+H)The DICOM header: acquisition parameters, contrast timing, slice thickness.
Save to File (Ctrl+Shift+E) / Copy (Ctrl+C)Export or copy an image. Exported images can contain patient information; follow local rules on where they go.
Duplicate Layout (Alt+J)Matrix window › Edit: copy a layout to change it.
Quick windowWindow menu: a lightweight viewer for single-image series and quick checks.

Breast imaging

  • Breast density a–d are Alt+1 to Alt+4 by default.
  • B (Toggle View) switches between 2D and tomosynthesis; Alt+B jumps from a point on the 2D image to the matching tomo slice (hidden in some setups). A position indicator shows where you are in the tomo stack.
  • Quadrant zoom (Q) steps through each quadrant at full resolution; an optional mammography keypad is available.
  • CAD marks: View › Show/Hide Graphics › Show CAD Graphics.
  • Breast MRI tools include 4D navigation and time-intensity curves (Stack right-click › Measure › Time Intensity ROI Circle).
  • Automated density results may appear if your site has density software.
  • In the US, mammograms must be read on a monitor cleared by the FDA for mammography.
  • Which of these you have depends on your site's licenses and setup.
12
Reading images

Measure, annotate, zoom, window/level

Measure and annotate

KeyFunction
DDistance
Shift+DOrthogonal distance
NAngle. It can be set to 4-click (two separate lines, like a Cobb angle), e.g. for scoliosis.
HHistogram circle (HU)
R / Ctrl+RROI circle / ROI area
AArrow
OCircle
EMultiple graphics
Backtick (hold)Show all annotations
TText
Ctrl+Shift+PShow pixel value
Deleting a measurement or annotation

Hover the mouse over the measurement or annotation and press Delete; it's removed from that image. Handy for a quick check you won't report (an aorta, a CBD, a spleen) so the measurement isn't left behind. To just hide graphics, right-click › Show/Hide Graphics › Show Graphics turns them all on or off (Shift+G); separate toggles hide a colleague's (Show Graphics by Other Users), DICOM and CAD graphics. There's no save step: measurements and annotations are kept automatically, including ones made on priors, and stay for everyone who opens the exam until deleted (unlike viewers that discard unsaved marks).

Careful: these delete things
  • • Del depends on what's under the pointer. With no annotation there, it's Remove from Worklist… (and Remove from Demonstration in the Demonstration menu). If you pressed it and nothing disappeared from the image, check the exam is still where you expect.
  • • Shift+Del is Delete Series (patient history and thumbnail right-click menus): it removes a series from the exam. To get a series off the screen, change the layout instead.
  • • Delete All Graphics in Series / in Presentation clears every annotation in the stack, or on every image on screen. There's no command for just one image; delete those one at a time.
  • • Delete Report (Tools › Reporting) and Delete Presentation (File) are rarely needed; read the prompt before confirming.
  • • Right-click an exam › Administration holds Delete Online Examination, Permanently Delete Archived Examinations/Series and Reset Examination to Original. These are normally for PACS staff only; report it if they're enabled for you.
  • • Space (Reset to original images) undoes view changes such as zoom and window/level, but leaves annotations in place.

Zoom, window/level and image handling

KeyFunction
Z / Shift+ZZoom in / out
GMagnifying glass
QQuadrant zoom
Ctrl+ZPixel to pixel 1:1
Ctrl+Shift+Alt+ZZoom to fit window: undo zoom. Zoom centers on the cursor, not the middle of the pane; for stacks of plain films, mapping this key and Ctrl to mouse or keypad buttons saves a lot of reaching.
Shift+Alt+ZTrue size
WWindow/level control
Ctrl+WNext window/level preset
IInvert
Ctrl+Shift+WNext palette
SpaceReset to original images: removes temporary changes such as zoom, flips and rotations. A flipped or rotated image always shows a small marker until reset.
Ctrl+Alt+RReset presentation: puts the exam back to its original hanging after you've moved or swapped series.
[ / ]Rotate 90° counter-clockwise / clockwise
Shift+H / Shift+VFlip horizontal / vertical
Ctrl+BToggle crop
Ctrl+MSharpen edges (formerly Ctrl+E). Sectra has no exact match for the CLAHE filter some other viewers have; this and Enhance contrast (M) are the closest, and readers split between them, so both sit on neighbouring keys.
MEnhance contrast (formerly Alt+E)
Ctrl+SpaceRefine all images
F6Hide image information
Shift+SShow scanograms

Key images, presentations and teaching

KeyFunction
NumPad /Set key image
, / .Previous / next key image
Shift+KView key images
Ctrl+NumPad /Set key series
NumPad *Reset key image
Ctrl+SSave presentation
Ctrl+Shift+NAdd to report presentation
Ctrl+KLink to image in report
Ctrl+Alt+DAdd to demonstration (conference)
Ctrl+ESet follow-up (tech QA)
Ctrl+Alt+GClear follow-up
Conferences and tumor boards

Saved presentations, report presentations and Add to Demonstration are the building blocks for conference lists with saved hangings and annotations.

Lesion tracking (RECIST)

If your site has it, lesion tracking follows measured lesions across exams and can send the measurements into the report. Right-click an exam in the patient history list › RECIST to add it as a follow-up. Menus vary by site and license.

Newer measurement tools (version-dependent)

  • Curved Distance (right-click › Measure): measure along a curve, e.g. a vessel, bowel, ureter or spinal length.
  • Show Graphics from All Slices (View › Show/Hide Graphics): show annotations from every slice on the current one (the backtick key by default, unconfirmed).
  • Blackout Tool (toolbox): black out burned-in patient details before using images for teaching, publications or conferences.
13
Making it yours, carefully

Customization and resetting to defaults

Start from the shared defaults

Avoid personal changes to menus, toolbars, hotkeys and worklist columns while you're learning. Everyone starting from the same baseline is what lets support help you quickly.

What happens when you customize

  • Changing a setting detaches that part of your profile from your organization's default, including every future improvement to it. Even a single key-map change can stop updates reaching that menu.
  • Prefer mapping mouse buttons in your mouse software over changing Sectra's own settings when you can.
  • If you do change something, screenshot the default first and keep a list of what you changed. Review it before go-live, so standard instructions (“just click…”) still make sense to you and you can give them to others.
  • A tool you use often that's buried under More in a right-click menu can be moved up front later; ask your PACS team rather than rearranging menus yourself during rollout.

Mice, trackballs and keypads

  • Sectra runs as a normal Windows application, so Razer Synapse, KensingtonWorks and Logitech G Hub work, although Sectra doesn't formally list them.
  • The old Logitech SetPoint utility is discouraged: it's retired and has been associated with crashes of the display-calibration service.
  • G Hub macros may not work when the mouse is in on-board memory mode (for example at a workstation without G Hub installed).
  • Ctrl + F-key combinations can't be mapped in Sectra; Shift + F-key can.
  • Each command takes only one shortcut key, so window/level presets can sit on the number pad or on the top-row numbers, not both.
  • Sharing exported mouse/keypad profiles with colleagues helps less tech-oriented readers.
  • 3D mice and keypads (e.g. 3Dconnexion SpaceMouse) also work with IDS7, with radial menus and macros.

How to reset to the defaults

  1. 1Check the role next to your name in the upper left of the Information window is the radiologist role. If not, log in again with the right role.
  2. 2Log off and log back on. This loads the newest defaults.
  3. 3Go to Tools › Options › Menus and Toolbars (Ctrl+Shift+O opens Options). Press Reset (reset all), then Apply, then OK.
  4. 4Close and reopen Sectra. Closing the login window too may be needed.
  5. 5Check: right-click an image › menu › navigation, and compare with your reference card. If it still differs, tell your PACS team.

Finding a function and changing its key

  1. 1Look the function up in the Shortcuts or A–Z index tabs. The “where to set it” path is the place to open first.
  2. 2In Sectra: Options › Menus & Toolbars, then click down the path shown (for example Image Window › Image Pop-up › Zoom).
  3. 3Select the function, click in the Shortcut key box, press the key, then Assign. If the key is already taken, Sectra warns you and names the function using it.
  • Help › Shortcut keys lists every shortcut you currently have.
  • In Menus and Toolbars, the left list is the menu you're editing and the right list is every command available; use Up / Down to reorder, and the Filter box to find a command by name. Clear removes a key; “Currently assigned to” shows what a key does now.
  • To change what a menu contains, drag tools from the right-hand list into it, or use Add and Remove.
Before you reassign anything

It detaches that menu from shared updates. The same function can show different keys in different menus (Sectra's own defaults put Show Documents on Ctrl+Shift+D under View but D in the Image Pop-up), because Sectra binds keys per location.

When your site updates its keys

If you've customized your own shortcuts in Options, your personal settings may not pick up key changes your site rolls out later. Site key cards are usually dated; when a new one comes out, replace printed or saved copies and check the changed keys still do what the card says.

14
Making it yours, carefully

Fine-tuning your settings

Personal display settings that don't change shared menus or hotkeys: presets, corner text, mouse buttons, scroll speed and fonts.

Settings live in Options (Tools › Options, or Ctrl+Shift+O; pick your user, then Continue). Some finer settings are only in Advanced Configuration, which has a Search for box: type a word from the setting's name.

Options pageWhat it sets
Grayscale PresetsWindow/level presets per modality, and their number keys.
Image InformationThe text in each corner of the image.
KeypadAn external keypad's buttons.
LanguageSectra's display language.
Menus & ToolbarsWhat's in each menu and toolbar, and every shortcut key.
MouseMouse buttons and double-click actions.
Report TemplatesReport templates.
Search PanelThe default search fields.
Slab PresetsSlab thickness presets for MPR/MIP.
Advanced ConfigurationEverything else, found by searching.

Window/level presets

  • Tools › Grayscale Presets lists the presets per modality; they matter most for CT.
  • The Shortcut column is the number key for each preset (top-row numbers: 1 abdomen, 2 bone, 3 brain, 4 liver, 5 lung, 6 vessel, 7 subdural, 8 stroke, 0 min/max). Double-click a value to change it. Ctrl+W steps through presets.
  • Reset puts a modality's presets back; Remove deletes one. Min/max shows the full range of values.
Example CT presetCenterWidth
Brain4080
Subdural80215
Stroke4040
Lung−4001800
Mediastinum50350
Abdominal soft tissue50400
Liver30150
Spine soft tissue50250
Bone4001800
PE250550

Image information (the corner text)

  • Options › Image Information sets what metadata shows (name, MRN, age, sex, series and image number…), per modality and per corner of the image. Thumbnails have their own setting.
  • There are three levels: minimum, medium and maximum. Switch while reading from the image window's Image Information menu.
  • Set the starting level in Advanced Configuration: search “image information” and change the default image information level.
  • Give the levels hotkeys in Options › Menus and Toolbars › Menu Bar › Image Information.
  • The same page sets the corner text's font and color, the calipers, and whether patient orientation markers show.
  • Tip: keep one level bare-bones, and put series and image number side by side so you can cite a finding's location quickly.

Mouse buttons

Options › Mouse sets what each button does, separately for single images (e.g. radiographs) and for stacks/MPR (e.g. CT). Reset All goes back to Sectra's defaults. The default setup:

InputSingle images (XR)Stacks and MPR (CT, MR)
Left dragWindow/levelWindow/level
Middle dragMove series to another viewportMove series to another viewport
Middle click, then dragBrowseBrowse
Right dragPanPan
Right clickToolboxToolbox
Right holdHighlight series in thumbnailsHighlight series in thumbnails
Back thumb button + dragZoomZoom
Forward thumb button + dragPanMove crosshair
Left + right drag—Browse
Left + middle dragFree rotateFree rotate
Middle + right dragWindow/level of a regionWindow/level of a region
WheelZoomStep through images
Right hold + wheelPrevious / next seriesPrevious / next series
Shift + wheel—Slab thickness
Left double-clickViewport to 1x1 and backViewport to 1x1 and back
Ctrl + double-clickPixel to pixel (1:1)Pixel to pixel (1:1)
Shift + double-clickSet crosshairSet crosshair
Middle double-clickStart cine (scroll to stop)Start cine (scroll to stop)

Using your own mouse? Program a button to send a key in the mouse's software (say Shift+F9), then map that key to the Sectra command you want.

Also on the Mouse pageChoices
Double-click actionsChoose what each double-click in the gestures table (Navigating series) does, for the image window and the Quick window.
Browsing a tiled stackScroll one line at a time, or one page at a time.
Window/level directionsDefault: drag up/down for width, left/right for center. Alternate swaps them. Either direction can be flipped.

Finer adjustments in Advanced Configuration

To changeSearch for
How fast dragging scrolls through a stack“Browse mouse sensitivity” (double-click to edit the number)
Font size of the worklist, patient history, Matrix window and thumbnails“font”
Crosshair too big“crosshair”, then choose Minimal (a dot instead of lines)
Default image information level“image information”
Whether the crosshair or localizer is on when an exam opens“Crosshair default mode”, “Localizer default mode”
Scanograms shown by default“Scanogram default mode”
Scrolling past the last image wraps to the first“Stack scroll wrap”
15
Making it yours, carefully

Smart display protocols

  • Smart Display Protocols (SDPs) are hanging protocols you create and save on the fly while reading.
  • They're designed mainly for CT and MR, where they give the most consistent results, but aren't limited to them.
  • Next time you open a similar exam, Sectra picks the best-matching SDP and hangs the available series the same way.
  • Treat an SDP as a good starting point; series vary between exams, so expect some manual adjustment.

Building one

  1. 1Set the partitions: right-click the mini monitors in the Matrix window, use the Image window toolbar, or View › Monitor Partitions. To start from scratch, Clear Presentation empties every partition and removes extra layouts.
  2. 2Drag series from the current and comparison exams into the partitions (from the Matrix or Image window). Series from the current exam you don't hang are added to the end automatically.
  3. 3Add or remove layouts until it looks the way you want; remove any you don't need.
  4. 4In the Image window, apply what you want saved with it: sync groups, clinical applications, cine loop, stack tile, Show Window/Level Control.
  5. 5Click Save Display Protocol on the toolbar. Keep the auto-generated name (modality, body part, number of comparisons) and only add small details; duplicate names aren't prevented.
  6. 6Choose to save only the current layout or all layouts, then Save. You can remove layouts later but not add them.
Presets, orientation and zoom go in the editor

Window/level presets, slab presets, orientation and zoom can't be saved from the Image window. After saving, click to refresh and apply the new protocol, then use Go To Display Protocol to open the Display Protocol Editor and set them per series (double-click a series, or Settings on the toolbar). Click Save in the editor when done.

In the Display Protocol Editor

  • Remove unwanted layouts.
  • Edit comparison relationships: Previous (older than the current exam), Next (newer), Most recent, or Oldest of that exam type. Each goes further back too: 2nd most recent, 3rd previous and so on.
  • Layout settings: “Show layout only when its comparison examinations exist”, “Hide layout when comparison examinations exist”, or “Hide layout when empty” (for series that aren't always acquired).
  • “Lay out extra images automatically in current exam” hangs extra current series; “Auto open of additional exams” opens similar comparisons so Up / Down (newer / older prior) reach ones not hung. “Mirrored synchronization” mirrors left and right mammography images (needs a license).
  • Save keeps changes to this protocol; Save All saves every protocol you changed.
  • Right-click a protocol to rename, delete or disable it. Copying one to colleagues is permission-based; ask your PACS administrator.
  • Stack sorting, and keeping series like scouts and dose reports from hanging, are Series Type Settings; ask your PACS administrator.

When Save is greyed out

  • You need the permission and license to create SDPs.
  • An exam in the presentation is missing its modality or anatomy.
  • More than four comparison exams are included.
  • No images from the current exam are on any layout.
  • Hover over Save Display Protocol: its tooltip says why it's disabled.

Good to know

  • Image projection decides what hangs where: hang an axial CT series in a partition and that partition only takes axial series.
  • When several protocols could apply, they're typically ranked by how well they fit the station's monitors first, then by owner (yours, then your role's, then the system's), then by matching priors. So changing a station's monitor count can change which protocol wins.
  • An SDP applies to every exam with the same anatomy and modality, so make one per anatomy and modality.
  • One SDP covers left, right and bilateral exams; Sectra only opens comparisons with matching or no laterality.
  • All the usual navigation works in an SDP: the exam switcher, series changes, next/previous set, newer/older comparisons, anatomic linking and Shift+Q to triangulate.
16
Around the edges

Saving interesting cases

Teaching file keywords

  • Right-click the study in the patient history list › Teaching files, then type a keyword. Optionally add a teaching file comment.
  • Keywords are visible to everyone. For personal ones, start with your initials or last name. View all shows existing keywords; never delete other people's.
  • To find them: Search, then change the search field to Teaching file keyword; matches appear as you type. You can also build a personal worklist filtered by keyword.
  • Ctrl+Alt+D adds images to a demonstration (conference) list.

Static worklists

A static worklist only changes when you change it. Right-click User Worklists › New Static Worklist (or New Folder) and drag studies into it; folders and sub-folders keep them organized. To prepare a conference such as tumor board:

  1. 1Create a static worklist for the conference.
  2. 2Open the exam in the Matrix window and use Clear Presentation to start from scratch.
  3. 3Choose the monitors and partitions, place the images and add layouts as needed.
  4. 4Annotate in the image window. Annotations aren't private: anyone who opens the images later sees them.
  5. 5In the Information window, add the exam to the static worklist with Save current presentation ticked, so your layout is kept.
  6. 6Repeat for each case, then reopen them from the list to check the saved presentations.
17
Around the edges

UniView, chat, training and getting help

UniView vs. IDS7

UserUniView (web)IDS7 (desktop)
RadiologistAll imagesRadiology images by default; can toggle to show non-radiology images
Radiology technologistAll imagesRadiology images by default; toggle available
Non-radiology clinicianAll imagesDepends on role; some can only launch IDS7 from UniView

UniView is useful for checking how your prelim or report looks to referring clinicians.

  • In UniView you can typically create and edit only arrows, angles, distances and ROI areas; other measurements made in IDS7 (ellipse, ratio, ETDRS grid…) show but can't be edited.
  • It has a localizer toggle, layouts from the layout folder on its toolbar, and can show up to about nine series side by side.
  • Its Help menu opens its own user guide. It isn't a full diagnostic workstation; for diagnostic review, use full image quality.

Sectra chat

  • Built-in chat makes it easy to share a case with a colleague for a consult.
  • The new-message notification is a subtle flash and easy to miss; the default can be changed centrally.
  • Chat notifications and archive-retrieval messages can sit on top of the image; move or close them before reading that area.

Peer review, co-reading and AI

  • Peer review can be built into the reading workflow: random review worklists, optional anonymous feedback, notifications to the author and arbitration for disagreements.
  • Reports can be co-authored, and double reading can be structured, if your group turns it on.
  • Scheduled conference (MDT) worklists build on Demonstration lists (see Conferences and tumor boards).
  • AI results open inside IDS7; how they look (overlays, flags) depends on the AI apps your site licenses.
  • Restricted records can ask for a “break the glass” reason before opening; that access is audited.
  • Which of these you have depends on your site.

Training and help

  • Keep your site's newest keyboard reference card at hand; hotkeys get adjusted over time.
  • F1 opens Sectra's full IDS7 user guide for the version you have installed.
  • Sectra's vendor training modules (training.sectra.com, e.g. Overview for Radiologists) are generic but a good base; your organization may have you register through its own learning system.
  • Ask PACS about the downtime plan before you need it: some sites have a web downtime viewer with only recent images (a few weeks) during upgrades. Know where its link lives.
  • 3D and MPR are usually rendered on the server, so they should work from home too; report it if they're slow there.
  • Send problems and requests through your organization's official feedback channel so they're tracked, not only mentioned in chat.
  • Your PACS team configures monitor layouts and pushes missing installs; worklist content questions go to PACS plus your group's lead.
Going live before formal training?

Review the reference card in advance, get monitors configured at every workstation you'll use, and rehearse time-critical workflows (stroke alerts, ED reads) before you need them.

18
When something is off

Troubleshooting

SymptomLikely cause and fix
No Sectra iconConnect to the network and leave the PC on; the push can take a while. Otherwise ask PACS. Never hand-install.
No hanging protocols; menus or hotkeys look wrongWrong role. Log in with the radiologist role; uncheck auto-choose last enrollment if needed. Then reset menus.
No desktop-sync option at loginExpand More options. Still missing: PACS (possible duplicate account or wrong group).
Auto / Dictate / auto-next buttons missingDesktop sync not on, or the Information window is too wide in landscape and hides the down-arrow.
Dictation or EHR not following the examLaunched without sync, or not from the integrated icon. Relaunch from the icon with sync checked.
“Reporting integration out of sync with IDS7”Common early on because the integration listens passively. Report it if it continues.
Images on the wrong monitorsWorkstation-specific layout, or the wrong Windows main display. Make the Information window screen the main display, then ask PACS to set roles by position, for each workstation including home.
Worked yesterday, scrambled todayWindows renumbered the screens after a cable, dock, KVM or driver change. Redo the Windows display layout (Identify, drag the tiles), then have the roles reapplied.
Wrong on every station you log intoSettings following your account onto stations with different screens. Ask PACS for per-workstation monitor settings.
An image window seems not to open, or some series are missingIt may have opened behind the Information window (bring image windows to the front), or the hanging expects more monitors than the station has (look for the warning icon; pick a protocol for your monitor count).
Mouse jumps to the wrong screenWindows' screen tiles don't match the desk. Drag them into physical order and align the top edges.
Images blurry, or measurements and true size look offNon-native resolution or scaling above 100%, or the monitor size isn't set in Sectra.
Side-by-side screens differ in brightnessUnmatched or uncalibrated displays, or brightness changed from the monitor buttons. Report it to display QA or the physicist.
“No permission to view patient data”Account not fully provisioned. Contact PACS.
Exam disappeared from the worklist after openingExpected (status changed). Use your history.
Assigning several exams fails, or the report keeps popping upTurn Auto-dictate off while assigning; turn both Auto buttons on in your unread-exams worklist.
Comparison field emptySend comparisons (;) with the report open and priors displayed.
Rearranged series and can't get the original hanging backReset presentation (Ctrl+Alt+R) restores the display protocol's layout.
Prior not anatomically linkedCheck both crosshair options; rehang via the first DP; or NumPad +.
F7/F8 moving one viewport instead of the whole setReset menus: log off/on → Options › Menus and Toolbars › Reset › Apply › OK → restart.
Shortcut shows in the menu but does nothingCan happen after resets; log out and in again. Check for a dictation key clash (F7).
Addendum stuck in DraftReopen the addendum and delete it again.
The EHR still shows the previous patient after you close an examDesktop sync should change or clear the chart; some setups only follow the next patient. This is a wrong-patient risk: report it with details (closed by hand or auto-next; whether opening the next exam updates the chart). Until fixed, close the chart yourself and check the patient before charting.
Exams hang wrongly in the first weeks, or the same exam hangs differently on two stationsDisplay protocols usually need tuning after go-live, and Sectra picks a protocol partly by how well it fits the station's monitors. Report the station ID, number of screens, modality, protocol name and what hung where (a photo of the desk helps), since protocols are built centrally.
The history you need is only on the scanned order (requisition)Ask for the display protocol to hang the requisition first for those exam types. It helps most when the report template needs the history before anything else.
Sync warnings or the wrong patient while an old PACS is still installedDon't run the old PACS and Sectra at the same time; both try to sync with dictation. Close everything, including the dictation app, then open only one.
Font far too big or small at a new workstationDisplay settings follow your account. Change it in Advanced Configuration (search “font”).
Each exam shows as one row per patientInformation window › View › untick Show one row per patient.
Crosshair too largeAdvanced Configuration › search “crosshair” › Minimal.
Can't save a smart display protocolHover over Save Display Protocol for the reason (permission, missing anatomy, more than four comparisons, no current images).
Tomo cine too slowShift+. to speed it up; the default is an admin setting.

Adapted from a radiology group's first-timer's guide. Not affiliated with Sectra; confirm against your organization's current guidance.