Normal values

Age- and gestation-based normals you can calculate, plus common reference values. Each value names its source.

Abdomen

  • Common bile duct

    ≤ 6 mm with the gallbladder in situ; often allowed ~1 mm more per decade over 60. Up to ~10 mm can be normal after cholecystectomy.

    Common ultrasound practice (e.g., Radiopaedia, ACR practice parameter context)

  • Gallbladder wall

    ≤ 3 mm (fasting, distended gallbladder).

    Standard ultrasound reference

  • Liver length (adult)

    ≤ ~16 cm craniocaudal in the midclavicular line (some use 15.5 cm); larger suggests hepatomegaly.

    Standard ultrasound reference

  • Spleen length (adult)

    ≤ 12–13 cm; > 13 cm is splenomegaly.

    Standard ultrasound reference

  • Main portal vein diameter

    ≤ 13 mm (quiet respiration); larger suggests portal hypertension.

    Standard ultrasound reference

  • Main pancreatic duct

    ≤ 3 mm (head); slightly larger can be normal in older adults.

    Standard reference

  • Kidney length (adult)

    10–12 cm; a side-to-side difference > 1.5–2 cm warrants explanation.

    Standard ultrasound reference

  • Renal resistive index

    Adults < 0.70 (interlobar/arcuate arteries); > 0.70 is abnormal but nonspecific. Normally higher in neonates and older adults.

    Standard renal Doppler reference

  • Appendix

    Outer diameter ≤ 6 mm; > 6 mm (noncompressible on US) supports appendicitis.

    Standard US/CT criterion

  • Bowel caliber (3-6-9 rule)

    Small bowel ≤ 3 cm, colon ≤ 6 cm, cecum ≤ 9 cm.

    Standard radiographic/CT rule

  • Liver attenuation (unenhanced CT)

    Liver ≥ spleen. Liver < 40 HU, or liver minus spleen < −10 HU, indicates at least moderate steatosis (≥ 30%).

    Standard CT criteria (e.g., Park et al., Radiology 2006)

  • Main portal vein flow

    Hepatopetal with mild respiratory phasicity, ~15–40 cm/s; < ~16 cm/s, hepatofugal or to-and-fro flow suggests portal hypertension.

    Standard liver Doppler reference

  • Hepatic artery resistive index

    0.55–0.80. In liver transplants, RI < 0.5 with acceleration time > 80 ms (tardus parvus) suggests hepatic artery stenosis or thrombosis.

    Standard liver and transplant Doppler reference

  • Renal transplant resistive index

    < 0.70 normal; > 0.80 is abnormal but nonspecific (rejection, ATN, obstruction, compression).

    Standard transplant Doppler reference

  • Intrarenal tardus parvus

    Acceleration time > 70 ms (some use 100 ms) or acceleration index < 300 cm/s² suggests upstream renal artery stenosis.

    Standard renal Doppler criteria

  • Mesenteric artery stenosis (Doppler)

    Fasting PSV ≥ 275 cm/s in the SMA or ≥ 200 cm/s in the celiac axis suggests ≥ 70% stenosis.

    Moneta et al., J Vasc Surg 1991 and 1993

  • Adrenal limb thickness

    ≤ 5 mm (thinner than the adjacent crus); thicker limbs suggest hyperplasia.

    Standard CT reference (e.g., Vincent et al., AJR 1994)

  • Gallbladder size

    ≤ ~10 cm long and ≤ 4 cm transverse when fasting; larger suggests hydrops or obstruction.

    Standard ultrasound reference

  • Bowel wall thickness

    Small bowel and distended colon ≤ 3 mm; > 3 mm is thickened (collapsed bowel can look thicker).

    Standard CT reference

Vascular

  • Abdominal aorta

    < 3.0 cm; ≥ 3.0 cm is an abdominal aortic aneurysm.

    SVS / ACR definition

  • Ascending aorta

    < 4.0 cm in most adults; ≥ 4.0 cm is dilated.

    ACR / AHA thoracic aortic guidance

  • IVC (right atrial pressure)

    ≤ 2.1 cm with > 50% inspiratory collapse → RA pressure ~3 mmHg; > 2.1 cm with < 50% collapse → ~15 mmHg.

    ASE guidelines (Rudski et al., 2010)

  • Internal carotid stenosis (Doppler)

    ICA PSV < 125 cm/s: < 50%; 125–230 cm/s: 50–69%; > 230 cm/s: ≥ 70% (with plaque). Supporting: ICA/CCA PSV ratio < 2.0, 2.0–4.0, > 4.0; ICA EDV > 100 cm/s favors ≥ 70%.

    SRU consensus criteria (Grant et al., Radiology 2003)

  • Renal artery stenosis (Doppler)

    PSV > 180–200 cm/s or renal-aortic ratio > 3.5 suggests ≥ 60% stenosis.

    Standard renal Doppler criteria

  • Common iliac artery

    Normal ~1.0–1.2 cm in women and ~1.2–1.5 cm in men; ≥ 1.8–2.0 cm (or > 1.5× expected) is aneurysmal. Repair is suggested at ≥ 3.5 cm.

    Standard vascular reference; SVS guideline (Chaikof et al., J Vasc Surg 2018)

  • External and internal iliac arteries

    External iliac ~0.7–1.0 cm; internal iliac ~0.5–0.7 cm. Isolated internal iliac aneurysms are often treated at ≥ 3.0–3.5 cm.

    Standard vascular reference

  • Popliteal artery

    Normal ~0.7–1.1 cm; ≥ 2.0 cm (or > 1.5× normal) is aneurysmal, and repair is suggested at ≥ 2.0 cm.

    SVS popliteal aneurysm guideline (Farber et al., J Vasc Surg 2022)

  • Common femoral artery

    Normal ~0.8–1.0 cm; > 1.5× normal is aneurysmal.

    Standard vascular reference

  • Peripheral arterial stenosis (Doppler)

    PSV ratio (stenosis to proximal segment) ≥ 2.0 suggests ≥ 50% stenosis; ≥ 4.0 suggests ≥ 75%. Normal waveform is triphasic.

    Standard peripheral arterial Doppler criteria

  • Ankle–brachial index

    1.00–1.40 normal; 0.91–0.99 borderline; ≤ 0.90 PAD; > 1.40 noncompressible vessels.

    AHA/ACC PAD guideline (Gerhard-Herman et al., 2016)

  • Descending thoracic aorta

    Usually ≤ ~3.0 cm in adults (larger with age and body size).

    Standard CT reference

Chest

  • Main pulmonary artery (CT)

    ≤ 29 mm; larger, or PA larger than the ascending aorta, suggests pulmonary hypertension.

    Standard CT criterion

  • Cardiothoracic ratio

    < 0.50 on a PA radiograph; AP and supine films magnify the heart.

    Standard radiographic reference

  • Azygos vein

    ≤ ~10 mm on an upright radiograph; larger suggests raised right heart pressure or volume overload.

    Standard radiographic reference

  • Pericardial thickness

    ≤ 2 mm on CT or MRI; ≥ 4 mm supports constrictive pericarditis in the right clinical setting.

    Standard cardiac CT/MRI reference

  • Tracheal diameter (coronal)

    Men ~13–25 mm, women ~10–21 mm; larger suggests tracheobronchomegaly.

    Breatnach et al., AJR 1984

Pelvis

  • Endometrium — postmenopausal bleeding

    ≤ 4 mm makes endometrial cancer unlikely.

    ACOG Committee Opinion 734 (2018)

  • Endometrium — premenopausal

    Varies by cycle: ~2–4 mm menstrual, ~5–7 mm early proliferative, up to ~16 mm secretory.

    Standard ultrasound reference

  • Ovarian volume (PCOS criterion)

    ≥ 10 mL (or ≥ 20 follicles per ovary) meets the ultrasound criterion for polycystic ovarian morphology.

    International PCOS guideline (2023) / Rotterdam criteria

  • Prostate volume / PSA density

    Normal adult prostate ~20–30 mL. PSA density > 0.15 ng/mL/mL raises concern for clinically significant cancer.

    Standard urologic reference

  • Bladder wall

    ≤ 3 mm when distended (≤ 5 mm when not distended).

    Standard ultrasound reference

  • Post-void residual

    < 50 mL normal; > 100–200 mL is significant retention.

    Standard urologic reference

  • Testis

    About 4–5 × 3 × 2–3 cm (~12–25 mL); a > 20% volume difference between sides warrants explanation.

    Standard ultrasound reference

  • Varicocele

    Pampiniform veins > 3 mm, especially with reflux on Valsalva.

    Standard scrotal ultrasound criterion

  • Penile Doppler (after vasodilator)

    Cavernosal PSV > 35 cm/s normal; < 25 cm/s arterial insufficiency; EDV > 5 cm/s with good PSV suggests venous leak.

    Standard penile Doppler criteria

  • Uterus (adult)

    ~6–9 cm long, ~3–5 cm AP; larger in multiparous women, smaller after menopause.

    Standard ultrasound reference

Obstetric

Fetal Doppler: MCA-PSV, UA and CPR

Enter the gestational age and MCA-PSV, and/or the MCA and UA PI.
  • Nuchal translucency

    ≥ 3.5 mm (11–14 weeks) is increased.

    ISUOG / FMF

  • Fetal lateral ventricle (atrium)

    < 10 mm normal; 10–15 mm mild ventriculomegaly; > 15 mm severe.

    SMFM / ISUOG

  • Cisterna magna

    2–10 mm.

    ISUOG fetal neurosonography

  • Fetal renal pelvis (APD)

    < 4 mm at 16–27 weeks; < 7 mm at ≥ 28 weeks.

    UTD classification (Nguyen et al., 2014)

  • Amniotic fluid

    AFI 5–24 cm; single deepest pocket 2–8 cm.

    ACOG / SMFM

  • Cervical length

    < 25 mm before 24 weeks is a short cervix.

    ACOG / SMFM

  • Early pregnancy failure

    Diagnostic: CRL ≥ 7 mm with no heartbeat, or mean sac diameter ≥ 25 mm with no embryo.

    SRU consensus (Doubilet et al., NEJM 2013)

  • Placental edge to internal os

    Covering the os: placenta previa. Edge within 2 cm of the os: low-lying placenta (reassess in the third trimester).

    AIUM / SMFM / ACOG

Pediatric

Pediatric spleen, liver and kidney size

Enter the age (years and/or months) to see the normals.
  • Hypertrophic pyloric stenosis

    Muscle thickness ≥ 3 mm and channel length ≥ 15–17 mm are diagnostic.

    Standard pediatric US criteria

  • Infant hip (Graf alpha angle)

    α ≥ 60° normal (type I); 50–59° immature/dysplastic depending on age; < 50° dysplastic.

    Graf classification

  • Common bile duct (child)

    ≤ 3.3 mm (all 173 normal children, 1 day–13 years).

    Hernanz-Schulman et al., 1995

  • Renal collecting system wall (child)

    0–0.8 mm normal; ≥ 1 mm is abnormal.

    Robben et al., 1999

  • Hip joint effusion (child)

    Anterior capsule (both layers), supine, hip neutral: > 2 mm difference between sides is abnormal; no change with age.

    Robben et al., 1999

  • Mesenteric lymph nodes (child)

    Short axis > 5 mm is common in normal children (54%); > 8 mm suggests enlargement.

    Karmazyn et al., 2005 (CT)

  • Conus medullaris level

    Tip at or above L2–L3 is normal; below L2–L3 suggests a tethered cord.

    Standard spine ultrasound/MRI reference

Neuro & spine

  • Optic nerve sheath diameter (adult)

    > ~5 mm (3 mm behind the globe) suggests raised intracranial pressure; cutoffs vary 5.0–5.7 mm.

    Point-of-care ultrasound literature

  • Spinal canal (AP diameter)

    Lumbar < 10 mm absolute stenosis (10–12 mm relative); cervical < 10 mm absolute stenosis.

    Standard spine reference

  • Cervical prevertebral soft tissue

    ≤ 7 mm at C2 and ≤ 22 mm at C6 (adult lateral radiograph).

    Standard radiographic reference

  • Atlantodental interval

    Adults ≤ 3 mm; children ≤ 5 mm.

    Standard radiographic reference

  • Basion–dens interval

    ≤ 12 mm on radiographs (rule of 12); ≤ 8.5 mm on CT.

    Harris et al., AJR 1994; Rojas et al., AJNR 2007

  • Cerebellar tonsil position

    Up to 3 mm below the foramen magnum is normal; 3–5 mm borderline; > 5 mm is Chiari I.

    Standard MRI reference

  • Pituitary height

    ≤ 8 mm in most adults; up to 10 mm in young women and 12 mm in pregnancy and postpartum.

    Standard MRI reference

  • Evans index

    ≤ 0.3; > 0.3 indicates ventriculomegaly (e.g., in normal pressure hydrocephalus).

    Standard CT/MRI reference

General

  • Bone density T-score (DXA)

    ≥ −1.0 normal; −1.0 to −2.5 low bone mass (osteopenia); ≤ −2.5 osteoporosis.

    WHO criteria

  • CT attenuation reference

    Water 0; simple fluid < 20 HU; fat about −50 to −150 HU; acute blood ~50–80 HU; cortical bone > 700 HU.

    Standard CT reference

  • Lymph node (short axis)

    Most sites ≤ 10 mm. RECIST 1.1: ≥ 15 mm pathologic (target), 10–15 mm non-target, < 10 mm normal.

    RECIST 1.1 (Eisenhauer et al., 2009)

Based on the sources listed with each value. Educational aid only — not medical advice; always verify against the official guideline and use clinical judgment. Report a problem